AC analytical control

AC SIMDIS Analyzer

Model: Code: AC SIMDIS

Brand: AC analytical control

Description

Full range of SIMDIS applications determines boiling points up to C120.

The only SIMDIS dedicated inlet for best performance
AC 8634 analyzer for accelerated D 86 data of jet fuel and diesel
Crude Oil analyzer merges DHA Front End with High Temp SIMDIS Technique
Sulfur and Nitrogen SIMDIS solutions to determine sulfur and nitrogen distributions in Crude or finished products
Wax ASTM D 5442 application
Solutions comply with ASTM, CEN, DIN, IP and ISO SIMDIS methods
A broad set of calibration, reference and quality control samples completes each SIMDIS application
User group meetings and Performance Monitoring program help users network to maintain analyzer performance
Dedicated correlations and calculations are included for:
Correlation to Physical Distillation D 86 D 1160 (ASTM D 2887; IP 406; ISO 3924)- NOACK – DIN 51.581-2- MOV – ASTM D 6417- Conversion to volume % for crude oils- Cutpoints fractions- Flashpoint (ASTM D 7215)

Standard

ASTM D2887, ASTM D3710, ASTM D5307, ASTM D6352, ASTM D7096, ASTM D7169, ASTM D7213, ASTM D7398, ASTM D7500, EN 15199, EN ISO 3924, IP 406, IP 480, IP 507, ISO 3924

Hydrocarbon Group Type Analysis

Model: Reformulyzer M4:

Brand: AC analytical control

Description

Excellent Performance with High Value of Return
-Increases Profits with Fast and Accurate Analysis in 39 minutes for fast decision-making on product specification
-Robust design reduces operational cost per sample
-Excellent precision and accuracy contribute to higher profitability
-Extensive analysis scope from one single instrument

Maximum System Uptime through Robust and Intelligent Design
-Excellent olefin trap robustness for superior trap lifetime
-Nitrogen carrier saves cost and avoids helium supply chain risks
-Diagnostic Tool and certified AC quality control samples for system performance verification

Improved Ease of Use and More Flexibility
-Standard olefin method covers entire concentration up to 75%
-User-friendly design allows easy preventive maintenance by operator
-Intuitive Reformulyzer software includes extensive range of methods and pre-programmed modes
-Unique Reformulyzer User Group with interlaboratory comparison contributes to high confidence level and a strong QC program

Standard

EN ISO 22854, ASTM D6839, ASTM D5443, IP566, SH/T 0741, GB/T 28768-2012

Sulfur Selective Detector

Model: SeNse

Brand: AC analytical control

Description

Excellent Performance

  • Easy to use on-screen User Interface
  • Independent of CDS& instrument
  • Automated vacuum leak check
  • Use of synthetic air improves stability and reduces oxygen related risks!
  • Universal mounting of instrument on any leading GC brand(s)

 

Best in Market Performance for High Return on Investment

  • Best in market sensitivity
  • Pressure point in base ensures baseline stability
  • Enhanced furnace temperature control improves temperature accuracy and reduces downtime
  • New patented probe design improves catalyst capacity and stability of baseline

Standard

Complies to all SCD standardized methods:ASTM D5504, ASTM D5623, ASTM D7011, ASTM D7807

Tailored Solutions

code: Customized GC

Brand: AC analytical control

Description

Enhances Performance

  • Solves the toughest analytical challenges through a GC that is designed, built, and tested for your specific application, to perform exactly as desired for the particular sample stream
  • Provides solutions for any concentration level from trace analysis and percent level to screening/profiling and purity determination
  • Ensures long-term performance and easy maintenance
  • Offers a complete solution that meets the same high quality level as any of our other analyzers, with customized calibration and quality control samples included (if required/requested), user familiarization, and full customized documentation

Meets Any Standard

  • Designs solutions that comply with particular standard reference methods, a customer in-house method, or any list of components

Standard

D2504, D2505, D6159, D2712, D5303, D2163, D2593, D1945, D6228, D5917, D4492, D4424, D6563, D7057, D5713, D5917, D6229, D2427, D5134, D3524, D3525, D7011, D4735, D6021, D7652, D7807, D5441, D5501, D7266, D7796, D6142, D5790, D5507, D6142, D2580

Refinery Gas Component

code: Hi-Speed RGA

Brand: AC

Description

  • Performs analysis in 5 minutes
  • Applies to a broad sample scope of both gaseous and liquefied samples
  • Excellent repeatability through automated sample shutoff valve and sampling devices
  • Robust and cost-effective design with valves mounted on the dedicated left side to provide superior thermal control, leak free operation, and easy access
  • Automatically calculates gas properties with the AC GASXLNC™ software
  • Optional special unit to introduce gas samples, which provides an easy and leak free connection to the instrument

Standard

ASTM D2163, ASTM D2504, ASTM D2505, ASTM D2598, ASTM D3588, EN ISO 7941, IP 405, ISO 7941, EN 15984, DIN 51666, ASTM D1946, UOP 539, GOST 31371

Crude Oil Analyzer

Model : -

Brand: AC

Description

More Accurate Whole Crude Oil Analysis Optimizes Product Value

  • Based on high resolution DHA analysis to separate individual components for the light end of the crude oil up to and including C9 without quenching
  • Uses HT SIMDIS for the heavier components >C9 according to ASTM D7169
  • Built-in calculations ensure the amount residue (or sample recovery) is determined using an external standard
  • Intuitive AC software merges DHA and SIMDIS results into one boiling point distribution curve for the whole crude oil
  • Unique AC User Group with performance monitoring program (PMP)
  •  Includes certified AC Quality Control Samples dedicated to crude oilProven Compliancy
  • Compliant with ASTM D7169, IP 545, IP 601 and EN 15199-3
  • Optional unique combi inlet allows analysis of both light end in crude oil (DHA FE) and light petroleum streams (naphtha/gasoline) conform ASTM D6729, D6730, D6733 and D5134

Standard

ASTM D7169, D7900, IP 545, IP 601, EN 15199-3, EN 15199-4

Natural Gas Components

Model : NGA GPA 2261

Brand: AC

Description

  • Analyzes most natural gas streams according to GPA 2261
  • Uses the new Agilent Technologies 7890 Series Gas Chromatograph (GC) or the compact 6850 GC (One-Valve application)
  • AC GAS XLNC automates gas properties calculations and reporting
  • Optional on-line remote support by LAN connection available

Standard

GPA 2261

Natural Gas Components

Model : NGA GPA 2286

Brand: AC

Description

  •  Analyzes natural gas streams according to GPA 2286
  • AC GAS XLNC automates gas properties calculations and reporting

Standard

GPA 2261

Fast Total Olefin Analysis

Model: FTO D6296

Brand: AC

Description

  • Full determination of all olefins within 20 minutes
  • Applicable for all finished motor gasoline and naphtha streams
  • Application range: 0.2-35.0% olefinic streams
  • Excellent repeatability
  • Capillary column technology yield excellent separation capabilities
  • Maximum automation reduces operator involvement and improves accuracy of results
  • Automatic report generation

Standard

ASTM D6296

Thiophene in Benzene

Model : D7011

Brand: AC

Description

The AC Analytical Controls Thiophene in Benzene application meets ASTM D7011 standards by determining trace thiophene in refined benzene by gas chromatography and sulfur selective detection. The analyzer allows fast, continuous analysis and demonstrates excellent performance results.

The application resides on an easy-to-use Agilent Technologies 7890 gas chromatograph, configured with:

  • A split/splitless inlet (S/SL) for sample introduction
  • Electronic pneumatics control (EPC) for setting flow and pressure parameters
  • A sulfur selective detector (SCD) for signal generation
  • An automatic liquid sampler
  • A 30-meter capillary wax column

Standard

ASTM D7011

Refinery Gas Components

Model: Fast RGA (1058)

Brand: AC

Description

  • Characterizes the composition of refinery gases within twenty minutes
  • Allows the analysis of a broad sample scope
  • Uses the new Agilent Technologies 7890 Series Gas Chromatograph
  • Includes automated sample shut-off valve
  • Robust system uses inert tubing resistant to corrosive materials
  • Excellent detectability
  • The AC Gas and Liquid Sampling Device offers a variety of operational advantages

Standard

ASTM D2163, ASTM D2504, ASTM D2598, ASTM D3588, EN ISO 7941, IP 405, ISO 7941, EN 15984, DIN 51666, GOST 31371

Gas Analyzer

Model: AC UOP 603-13

Brand: Frank PTI

Description

The AC UOP 603-13 Gas Analyzer is a specialized solution for determination of trace CO and CO2 in hydrogen and light gaseous hydrocarbons analysis according to UOP 603-13. The method was developed by UOP based on an AC Analytical Controls design.

Because only CO, CO2, and (a part of) methane are directed to the analysis column, the analysis column remains free of interfering components, providing unambiguous identification and quantitation. High boiling hydrocarbons are back-flushed and directed to vent for a fast analysis in under 5 minutes, and rugged system performance over time.

Standard

UOP 603

BioDiesel All-in-One

Product code: All in One Biodiesel

Brand: AC

Description

High throughput, small footprint

  • Features a short analysis time
  •  Automates analysis with an optional Automatic Liquid Sampler
  • Combines all relevant biodiesel applications within one flexible system for a complete biodiesel solution

Innovative system design

  • Decreases operator intervention with the secondary programmable column oven – no need for the removal of columns or other hardware when switching applications
  •  Guarantees excellent long term results
  • Decreases costs due to time savings on operator time and spare parts
    Enhanced and user-friendly software
  • Reports all relevant information for each method
  • Checks data against specification (pass/fail)
  • Ensures traceability through calibration data
  • Automates column performance checks for easy quality control
    Enhanced features
  • Includes all calibration components, internal standards, and reagents for each method

Standard

Complies with the latest updates from ASTM D6584, EN 14103, EN 14105, EN 14110 methods and prEN 16300 for Iodine Value

Traces Oxygenates

Model: OxyTracer

Brand: AC

Description

  • Fast analysis of oxygenates traces in 25-30 minutes
  • The incorporated Deans principle provides excellent separation of oxygenate traces at sub-ppm level from bulk matrix.
  • Analyzers can be (optionally) fitted with second FID, various Gas – and Liquid Sampling valves with backpressure regulator ensure sample integrity is respected and data is accurate.
  • Lower detection level of 0.1 ppm (method dependent), Linear response from 0.1 up to 2000 ppm assures performance (method dependent)
  • Complies to standards ASTM D7754, ASTM D7423 and adds AC Oxytracer and Methanol in E85 methods

Standard

ASTM D7754, ASTM D7423

Boiling Point Distribution

Model: AC 8612

Brand: AC

Description

Extremely accurate reporting

  • Offers operator-independent results that are in line with good laboratory practice
  • Exceeds repeatability requirements of D86 method, resulting in less product giveaway
  • Uses dedicated AC quality control samples to assist operators in calibrating and validating the system, ensuring maximum analysis accuracy
  •  Incorporates True Boiling Point (TBP) reportingHigh throughput
  • Features a sample throughput that is twice as high as classical D86
  • Cycles in 10 – 15 minutesFully automated
  • Saves up to 75% in labor cost compared to traditional D86 labor costs
  • Reduces operator involvement through software automation of analysis, data handling, and calibration
  • Allows unattended, continuous analysis through a high level of automationHigh levels of safety
  • Eliminates potential fire hazards associated with D86 physical distillation and ensures high safety standards

Standard

application delivers ASTM D86 correlated data for naphtha and gasoline samples within ASTM D86 groups 0, 1, and 2 in 15 minutes.

FAME in Avtur Analyzer

Model: FAME

Brand: AC

Description

High throughput, small footprint

  • Features a short analysis time
  • Automates analysis with an optional Automatic Liquid Sampler
  • Combines all relevant biodiesel applications within one flexible system for a complete biodiesel solution
    Innovative system design
  • Decreases operator intervention with the secondary programmable column oven – no need for the removal of columns or other hardware when switching applications
  • Guarantees excellent long term results
  • Decreases costs due to time savings on operator time and spare parts
    Enhanced and user-friendly software
  • Reports all relevant information for each method
  • Checks data against specification (pass/fail)
  • Ensures traceability through calibration data
  • Automates column performance checks for easy quality control
    Enhanced features
  • Includes all calibration components, internal standards, and reagents for each method

Standard

Applications
BioFuels

CNS SIMDIS for Crude Oil

Model: SIMDIS for Crude

Brand: AC

Description

Simple Operation

  • Integrated software that allows users to completely control the application
  • No extensive software knowledge required
  • A suite of customizable reports available at the push of a button

Wide Boiling Range Coverage

  • Analyzes a wide variety of crude products, including everything from heavy gas oils to naphtha.
  • When combined with the unique AC Analytical Controls Detailed Hydrocarbon Analysis (DHA) Front End (FE) solution, the hydrocarbon distribution profile can be extended to include fractions under C9 (BP<151C) in the 1 report.

Excellent Analysis Performance

  • A post column vent for heavy component fractions protects nitrogen and sulfur detectors and avoids heavy residue build up
  • Excellent sensitivity and stability of the Sulfur Chemiluminescence Detector (SCD) and Nitrogen Chemiluminescence Detector (NCD) detects levels below 50 ppm depending on element and sample type

Standard

ASTM D2887, ASTM D3710, ASTM D6352, ASTM D7096, ASTM D7169, ASTM D7213, ASTM D7398, ASTM D7500, EN 15199, IP 406, IP 545, ISO 3924, ASTM D6417, ASTM D7807

Detailed Hydrocarbon Analyzer (DHA)

Model: DHA

Brand: AC

Description

  • Full range of DHA applications comply with ASTM D5134, D6729, D6730 and D6733
  • AC Fast DHA application for optimized separations in 28 minutes
  • Unique Combi system permits the analysis of both light petroleum streams and the light end in crude oil
  • DHA Front End application uses the AC pre-fractionator for the analysis of the light end in crude oil conform IP PM-DL
  • Improved Ease of Use and more Flexibility
  • Applications are compatible with major chromatographic data systems
  • Independent from Chromatography data system
  • Multi-Language Support: English, Chinese, Spanish, Russian, Portuguese, French, Korean
  • DHA Front End analysis results can be directly merged with High Temperature SIMDIS analysis in the SIMDIS software, for improved crude oil boiling point distribution results.
  • Predefined settings per sample type contribute to reliable peak identification

Standard

ASTM D5134, ASTM D6729, ASTM D6730, ASTM D6733, D7900, EN15199-4, IP601, GOST R 52714, GOST R 54275

Aromaticity

Model: MDA IP391, EN12916, D6591

Brand: AC

Description

  • Fast aromatic ring analysis in 25 minutes
  • Robust and easy-to-use HPLC technique
  • Proven Agilent Technologies instrumentation
  • Precise and independent pressure control achieved by pumping system
  • An optional autosampler fully automates the system
  • User-friendly software controls data handling, calibration, analysis, and data reporting
  • Complete system integration of hardware and software components
  • Application delivered factory-tuned for the IP 391 and EN 12916 methods
  • Assured performance with a linear response
  • Calibration and quality control samples assist you in calibrating and validating the system

Standard

ASTM D6591, EN 12916, IP 391, GOST R EN 12916

Boiling Point Distribution

Model: AC 8634

Brand: AC

Description

Extremely accurate reporting

  • Exceeds reproducibility limits of the d86 method, allowing optimized cut point precision and less product giveawayHigh throughput/speed
  • Sample throughput is twice as high as traditional D86Fully automated
  • Saves up to 75% in labor compared to traditional d86 labor costsHigh level of safety
  • Eliminates potential fire hazards often associated with physical distillation.

Standard

ASTM D2887, EN ISO 3924, IP 406, GOST 2177

Extended Hydrocarbon Oil Index

Model: HC Oil Index

Brand: AC

Description

Meets Industry Standards and Methods

  • Complies with ISO 9377
  • Incorporates additional reporting capabilities for aromatics
  • Innovative technologies

Works with all major chromatographic data systems

  • Features a specialized AC TPI-Injector for non-discriminating injections and precise results

High throughput and powerful capabilities

  • Optimizes separation in 40 minutes
  • Increases throughput with optional dual-channel or liquid autosampler

Standard

DIN H53, ISO 9377-2