– Pendulum capacity : Standard type (strength 0 to 1000mN per specimen)
Heavy-duty type (strength 0 to 2000mN per specimen)
– Prescision : +1%
– Specimen clamp : Pneumatic clamp with push button
– Number of specimens: Set the number of specimena laid one on the top of another. 1,2,3,4,5,6,7,8,10,12,14,16
– Input of a basic weight
– Error warning: When the tear value is not included in the range of 20 to 80%, the error lamp warms og this event
– Pendulum friction display
– Automatic setting of the zero point
– Data display
TAPPI T414
ISO1974
JIS P-8116
– Specimen size : 63mm long, 50 to 75mm wide
– Number of specimen : 16 (the number of specimens to be measured is determined such that test result are within 20 to 80% of full the scale)
– Test tear length: 43mm
– Tesr slit length: 20mm
TAPPI T414
ISO1974
JIS P-8116
– This machine finds uses in testing the tear strength of corrugated board base paper, roofing, woven textile and the like,
– Capacity : 0 to 1000, 0 to 2000 (graduation per sheet for 16-sheet specimen)
TAPPI T414
ISO1974
JIS P-8116
– This machine was developed with KRK’s own technology to test the tear strength of thin paper sheets, synthetic paper, cellophane or the like
– The maximum tear energy is 1/3 or 1/4 of the standard type (selectable). (option 1/16 satndard)
– The position of the chuck is the same as the standard type: the chuck is 27.5 degrees from the vertical line passing the rotation axis with a rotation radius of 104 mm
– Pendulum capacity : 0 to 300mN
– Gloss is one of the important factors for printing paper; the reflection at 75 degrees is wide spread for general uses, except for papers of high gloss. The principle of this machine is as follows: Gloss amount of normal reflections is measured by irradiating light beams to the specimen at 75 degrees
– Incidence angle: 75±1°
– Life of lamp: approx, 10,000 hours
– Standard plate: one plate, black-colored
JIS P-8142
– Vapor permeability is expressed by the mass of vapor that passes through a unit area of specimen at a certain temperature and humidity.
– This tester measures the quantity of water transmission. Test procedure: put silica gel in an aluminum cup, and close the cup with a specimen; leave them at 40℃, 90% RH for a certain span of time, to measure the mass (in grams) of vapor transmission.
– Components 12 aluminum cups, 12 glass Petri dishes, 12 aluminum rings, 1 cup base, 1 guide, 1 weight about 500g
– Accessory wooden case
ISO 2528
JIS Z-0208
– Heat plate size 15mm wide×200mm long
– Temperature max. 200℃
– Compression pressure 0.5MPa
– Compressioin pneumatic
– Compression time 0.2sec. to 10min
– Upper heating bar heater 300W, temperature sensor inserted
– Lower heating bar with built-in impulse heater
– Specimen standard crepe paper 55 to 65g/m2
– Clamping area 5mm wide×25mm long
– Total clamping pressure 6,300kgf, pneumatic, steplessly variable
– Service air pressure 0.8 to 0.9MPa in maximum pressurization
– Tooth geometry pitch 1.85mm, inclination 10°, for non-standard specimens will be determined on the basis of experiments
– Interval between upper and lower teeth max. 5mm
– Clamping time 0.5 to 100min
– Heating cartridge heater with tooth plate inserted, upper and lower heater 250W each
– Temperature max. 150℃
– Temperature control PID and manual regulator
– Pressurizing surface 200×200mm (effective area)
– Pressure 1,000 to 1,500N (total pressure)
– Temperature max. 150℃
– Heater 100V 1kW
– Timer max. 30 sec.
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |